ECG | Input dynamic range | ±(0.5mVp~5mVp) |
Differential input impedance | ≥10MΩ |
Bandwidth | 0.05~150Hz (Diagnostic) |
0.5~40Hz (Monitoring) |
1~20Hz (Operation) |
CMRR | ≥90dB (Diagnostic) |
≥105dB (Monitoring & Operation) |
Sensitivity selection | ×1/4, ×1/2, ×1, ×2, ×4 and Auto |
Sweeping speed | 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s |
HR measuring range | 15~350bpm |
HR accuracy | ±1% or ±2bpm, whichever is greater |
Pacemaker pulse detection and rejection function |
|
RESP | Measuring range | 0~120rpm |
Measuring accuracy | ±5% or ±2 rpm, whichever is greater |
TEMP | Measuring range | 21.0~50.0℃ |
Measuring accuracy | ±0.2℃ from 25~45℃ |
NIBP | Technique | Oscillometric method |
Typical measurement time | <30 seconds (adult cuff) |
NIBP measuring range | SYS: 40~275mmHg (Adult) 40~200mmHg (Pediatric) |
| 40~135mmHg (Neonate) |
NIBP measuring range | DIA: 10~210mmHg (Adult) 10~150mmHg (Pediatric) |
| 10~95mmHg (Neonate) |
NIBP measuring range | MAP: 20~230mmHg (Adult) 20~165mmHg (Pediatric) |
| 20~110mmHg (Neonate) |
NIBP measuring accuracy | Mean difference: ±5mmHg |
| Standard deviation: 8mmHg |
NIBP measurement mode | Manual, Auto, STAT, Multi-cycle mode |
Auto measuring intervals | 1-480min |
SpO2 | Technique | Dual-wavelength optical method |
Measuring range | 0%~100% |
Measuring accuracy | Arms are not greater than 2% for SpO2 range 70~100%. |
PR measuring range | 30~250bpm |
PR measuring accuracy | ±2bpm or ±2%, whichever is greater |
Low perfusion performance | As low as 0.3%. |
CO2 | Technique | Infrared optical method |
Sampling mode | Sidestream or Mainstream |
Measuring range | 0~150mmHg |
Measuring accuracy: | 0~40mmHg ±2mmHg |
41~70mmHg ±5% of reading |
71~100mmHg ±8% of reading |
101~150mmHg ±10% of reading |
Flow rate | 50ml/min ±10 ml/min (Sidestream) |
Cerebral State Monitoring (CSM) | EEG sensitivity | ±400µV |
Noise level | <2µVp-p, <0.4µV RMS (1~250Hz) |
CMRR | >140dB |
Input impedance | >50Mohm |
CSI and update | 0-100. filter: 6-42Hz, 1 sec. update |
EMG% | 0-100 (logarithmic) |
filter: 75-85 Hz, 1 sec. update |
BS% | 0-100. filter: 2-42 Hz, 1 sec. update |
IBP | Technique | Strain gauge transducer |
| Input sensitivity | 5µV/V/mmHg |
| Measuring range | -50~300mmHg |
| Measuring accuracy | ±2% or ±4mmHg, whichever is greater |
| Measuring positions | ART, RAP, PA, LAP, CVP |
| ICP, AUXP1, AUXP2 |
| Calibration | zero calibrating |
Cardiac Output (C.O.) | Blood temperature | 23-43℃, accuracy: ±0.5℃ |
measuring: range |
Injecta temperature | 0-20℃, accuracy: ±0.5℃ |
measuring: range |
Measuring range | 0.2~20 L/min |
Measuring accuracy | ±0.2 L/min or ±10%, whichever is greater |
Other Specifications | Power supply | AC 100V-240V, 50/60Hz, 60VA |
Built-in lithium battery | 11.1V/4400mAh |
Display | 12.1 inch TFT display |
Alarming method | 3 levels audible-visible alarm |
Networking | Ethernet |
Standard configuration | ECG, Respiration, SpO2, PR, NIBP, Temperature |
Option | Touch Screen, 2-IBP, EtCO2, Nellcor SpO2, SunTech NIBP, 12-lead ECG, Cardiac Output, Cerebral |