- Coronary Stents Coronary Balloons Catheters Guide Wires Introducer Sheaths Accessories Peripheral Interventional Products
- Immunoassay Molecular Diagnostics Hematology Diagnostics POCT Lab Solution
- Structural Heart Diseases Products
- Vascular Access Blood Pressure Transducer Arterial Blood Sampler CVC Accessories IV Catheter Needle-free Connectors Insulin Injection Pain Relief
- Hemodialysis consumables Hemoperfutor Dialysis machine
- ECG Patient Monitor Oximeter
- Cardiovasculars Oncology Anti-infectives Central Nervous System Others
- Surgical Staplers Endoscopy Endoscopic Ultrasound System
- Trauma Implant Spinal Implant Artificial Joint Sports Medicine
- Pacemakers and Leads Equipments
- ELISA CLIA FIA
- Nucleic Acid Extraction Nucleic Acid Extraction & PCR Kits Real-Time PCR
- Thrombelastography Analyzer Blood Grouping Platelet Aggregation
- POCT - FIA Colloidal Gold Blood Glucose Cholesterol SARS-CoV-2
- NeoECG Holter Monitor Portable ECG Monitor AI-ECG Pocket ECG
- Patient Monitor Vital Signs Monitor End-tidal Capnography
- Fingertip Oximeter Handheld Oximeter Wrist Oximeter Wearable Oximeter All-in-One Health Monitor POCT Solution
- OBS Locking Compression Plate Locking Plates Conventional Plates Mini Plates System Screws Patella Ring - Patented Product Metal Pins Cable System
- Fusion Cage Cervical Fixation System Internal Fixation System Laminoplasty Plate System Percutaneous Kyphoplasty
- Hip System Knee System
- Suture Anchor Suture Button
Technical Specification
Test Sample | Fingertip blood(≥10ul) |
Blood Collection Method | Blood collection needle |
Detection Range | INR: 0.7-6.0 |
Preheat Time | ≤3 min |
Bluetooth Connection | Yes |
Test Time | 90 seconds |
Result Storage | 200 latest results |
Testing Temperature | 10-35℃ |
Reference interval | PT:7.0-15.0 s; INR:0.7-1.4 |
Hematocrit (HCT) | 30-55% |
Battery: | 4 AA/1.5V batteries |
Battery Life | About 200 tests |
Power Save Mode | Automated shutdown after 3 min with no operation |
Accessories | Disposable blood sampling needle (optional) |
Test Temperature | 10℃~35℃ |
Test Humidity | ≤80% |
Expiration date | 3 years |
Dimensions(L×W×H mm) | 145 x 69x 33 |
Weight | 160 g (without AA battery) |
Diagnostic Kits
Product Name | Product Model | Packing specification |
Prothrombin Time Test Strip | PT-S1-01 | 1 test/bag, 10 tests / box, 25 tests / box, 50 tests / box |
Thank You for Your Attention on Lepu Medical!
Email us with any questions or inquiries or use our contact data. We would be happy to answer your questions.